IOTFI
Log in to Eco Request a demo
Eco platform Hardware How it works Custom IoT Contact Log in to Eco Request a demo
Iotfi Systems Pvt. Ltd. · Bangalore

Industrial IoT,
end to end.

We build the data loggers that sit on your plant floor and the software that makes sense of what they send. Energy, emissions, vibration and vision — one pipeline, one portal.

Eco the platform
that runs it all
LIVE
Data loggers 5 MODELS
M0
M2
M5
Connectivity UPLINK
LAN · Wi-Fi · 4G
Analytics kWh/t
AI prediction ANOMALY
Camera feeds PTZ
LIVE
Alerts LIVE
!
2 thresholds crossed
SMS · EMAIL SENT
Scroll
5
data logger models in production
1
portal for every site you run
2 wk
from brief to custom prototype
CPCB
& SPCB uploads handled for you
eco.iotfi.in — live now

Eco is our monitoring portal.

Every logger we ship reports into Eco. Live IIoT data, predictive analytics, alerts, camera feeds and dozens of widgets you arrange yourself — the software half of an end-to-end IIoT application.

Open Eco ↗ Tour the platform
eco.iotfi.in/dashboard
Eco live data dashboard
Eco station view with live camera and trend
Eco live camera grid
Eco analytics dashboard
Eco alerts table
{{ label }}

Live data & analytics

Readings land in seconds. Trend, compare and export across sites, with prediction on the series that matter.

! SMS · Email

Alerts that reach someone

Thresholds, escalation and acknowledgement, so a breach at 3 a.m. is a message, not a discovery next morning.

Live camera streaming

PTZ control, history playback and remote monitoring of the stack, the floor or the panel room, next to the numbers it produces.

OT plant floor to IT analytics.

Scroll to draw the diagram tier by tier — instruments, loggers, Eco, the one-way diode, database servers, and the people reading them.

OT zone · plant network boundary IT zone · enterprise network 01 FIELD EQUIPMENT Analyzers gas · water · emissions MODBUS RTU · 1 s Flow Meters mag · ultrasonic · Coriolis HART · 4–20 mA Energy Meters kWh · kVAr · PF · demand MODBUS TCP · 1 s Chillers & HVAC load · setpoint · COP BACNET/IP · 5 s PLCs & RTUs control logic · live tags OPC UA · 100 ms Transmitters P · T · level · vibration HART · 250 ms Modbus RTU/TCP · OPC UA · BACnet/IP · HART · 4–20 mA 02 DATA LOGGERS Logger — Utilities polls analyzers, energy meters and the chiller plant RS-485 ×4 · GbE · 72 h BUFFER Logger — Process OPC UA change-of-value subs against the PLC / RTU layer NTP SYNCED · 3.2k SAMPLES/s Logger — Remote Skids cellular gateway, compresses and batch-forwards data LTE · MQTT · STORE & FORWARD MQTT / TLS · OPC UA · compressed batches 03 ECO — EDGE AGGREGATION ECO — Edge Collection & Orchestration redundant on-premise pair · still inside OT · no inbound routes from IT REDUNDANT PAIR Ingest & merge one broker, per-source back-pressure 01 Normalisation site → area → asset governed dictionary 02 Quality & rollups range · stuck · stale 1 m / 15 m / 1 h 03 Buffer & replay durable queue, survives outages 04 single egress feed · buffered, replayable 04 DATA DIODE DATA DIODE — UNIDIRECTIONAL GATEWAY hardware-enforced one-way optical link TRANSMIT ONLY RECEIVE ONLY return path physically absent — no fibre, no session, no route OT SIDE IT SIDE PROTOCOL BREAK · IEC 62443 ZONE SEPARATION replayed stream · schema validated 05 IT DATA PLATFORM Ingest Servers validate · idempotent write · dead-letter queue ~15k WRITES/s Time-series Historian compressed columnar store, continuous rollups per tag 10 YEAR RETENTION Relational / Asset DB asset hierarchy, tag metadata, calibration records, KPI defs POSTGRESQL Replicas & Backup read replicas serve all BI, snapshots + point-in-time PITR · 99.98% UPTIME 06 ACCESS & CONSUMERS READ REPLICAS · REST API · SQL GATEWAY · SSO / HTTPS · READ-ONLY Live Dashboards control-room walls, area overview screens 5 s REFRESH Reports shift, daily and regulatory compliance SCHEDULED PDF / XLSX Energy & OEE kWh/tonne, load profiles, anomaly detection ANALYTICS WORKBENCH Downstream Apps ERP · CMMS · notebooks pulling governed extracts REST · READ-ONLY Users Browsing operators, energy managers, planners, plant leadership SELF-SERVE ANALYTICS
OT zone — plant networkSecurity boundaryIT zone — enterprise networkData flow (arrow = direction)Blocked return path
One direction only

Every arrow points down. Nothing in IT can open a session back into OT — the diode has no return channel to route over.

Buffering at two levels

Loggers hold around 72 h locally and Eco keeps a durable queue, so a diode or IT outage backfills instead of losing data.

One tag model

Names are resolved once, in Eco. Historian, reports and APIs all speak the same site → area → asset → tag hierarchy.

Five loggers, one family.

Designed, built and supported in Bangalore. Every model reports into Eco from the moment it powers up.

All specs & datasheets →
COMPACT

M0 LAN & M0 4G

Palm-sized, DIN-rail mounted, four analog channels and RS-485. Pick Ethernet or a cellular uplink.

4 × ADC 4-20 mA RS-485 Wi-Fi 24 V
M0 LAN industrial data logger held in hand
M0 LAN front face and terminal labelling
M0 LAN analog input terminals, A-1 to A-4
M0 LAN power terminals, USB-C and RJ45
M2 industrial data logger held in hand
M2 twelve-way terminal block and label
M2 USB ports and RJ45

M2

The all-in-one. Twelve terminals of field I/O in a single DIN enclosure.

M5 industrial data logger, three-quarter view
M5 Ethernet and USB port panel
M5 terminal layout and labelling
EDGE COMPUTE

M5

Four cores, 1 GB RAM and 64 GB storage behind 4 ADC, 2 RS-485, 2 RS-232, DI, DO and relays.

M5 Serial industrial data logger held in hand
SERIAL DENSITY

M5 Serial

Eight serial channels — Ch-0 to Ch-7, each with Tx, Rx and ground — for analyser rooms and instrument racks that speak serial and nothing else.

8 × serial Ch-0…Ch-7 4 × ADC LAN optional 4G

Need a device that doesn't exist yet?

We take turnkey manufacturing of custom IoT devices — schematic, firmware, enclosure and the Eco integration that goes with it.

Get your prototype ready in just 2 weeks.

Contact us to get started

Get in touch.

Tell us what you need to measure and we will tell you which logger does it.

Phone
+91 7048968185
Office

Unit 101, Oxford Towers,
139, HAL Old Airport Rd,
H.A.L II Stage, Bangalore
Karnataka — 560008

{{ formNote }}